TearScience™ Meibomian Gland Evaluator
Key Features
Consistent Meibomian gland evaluation
Seamless Integration within practice
Efficient gland function monitoring
Functioning vs Blocked Glands
Images are for illustrative purposes only. Results may vary.
Learn More
With your consent, we will use your information to send you information about our products and services tailored to your interests through email. You may withdraw your consent at any time.
Please read our Privacy Policy.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
References:
1. TearScienceTM MGE IFU, United States
Indications & Safety Information
SUMMARY OF IMPORTANT SAFETY INFORMATION
Rx Only
FOR THE MEIBOMIAN GLAND EVALUATOR
INDICATIONS FOR USE
The Meibomian Gland Evaluator is a hand held instrument used by a physician to evaluate Meibomian gland secretions in adult patients during a routine eye examination. The instrument provides a standardized method to apply consistent, gentle pressure to the outer skin of the lower eyelid while visualizing the secretions from the Meibomian gland orifices through a slit lamp biomicroscope.
CONTRAINDICATIONS
No contraindications are known.
PRECAUTIONS
Do not depress the shaft to the endpoint of the spring. Do not apply any additional force after the shaft has been depressed approximately 6 mm. Applying additional force negates the benefit of using the instrument to apply standard force. Familiarity with use of a slit lamp biomicroscope is required to use Meibomian Gland Evaluator for assessment of the meibomian gland secretions.
WARNINGS
To ensure proper use of the Meibomian Gland Evaluator, review the warnings below. Do not use Meibomian Gland Evaluator if the package is open or broken. Do not use Meibomian Gland Evaluator if it appears broken or has sharp edges or rough surfaces upon initial inspection. Maintain proper infection control procedures including cleaning hands before handling the device and before evaluation of each patient. Disinfect the instrument with alcohol after each use and between patients. Avoid contact of the devices with the eye. Instruct the patient to look up and away to avoid injury to the cornea in the event the contact surface inadvertently touches the eye.
POTENTIAL ADVERSE EFFECTS
Potential adverse effects that are unlikely but may occur with use of the Meibomian Gland Evaluator include but are not limited to:
Skin abrasion (e.g., from a rough surface on the device)
Eye abrasion (e.g., from improper contact of the instrument with the eye)
Infection of the skin or eye (e.g., from improper or lack of disinfection after use and between patients) Allergic or toxic reaction (e.g., from exposure to any residue on device during user handling)
PP2023MGE4006