TECNIS PureSee IOL

TECNIS PureSee™ IOL with TECNIS SIMPLICITY™ Delivery System
Not all products are available in all countries
TECNIS PureSee™ IOL with TECNIS SIMPLICITY™ Delivery System
Not all products are available in all countries

TECNIS PureSeeTM IOL

– A purely refractive presbyopia-correcting IOL with continuous-power technology1

Designed for uninterrupted, high-quality vision, day and night1,2

Pure Quality Vision
Redefining Vision Needs

Addressing unmet needs of patients and surgeons3,5

Low level of disturbing visual

Low level of disturbing visual

Continuous crisp and clear vision

Continuous crisp and clear vision

Good vision day and night

Good vision day and night

Purely Refractive Design

Dysphotopsia profile comparable to monofocal IOLs6

Tecnis Symphony[^TM] IOL

TECNIS SymphonyTM OptiBlueTM Extended Range of Vision IOL

Tecnis Puresee[^TM] IOL

TECNIS PureSeeTM IOL

Tecnis Monofocal 1-Piece IOL

TECNISTM 1-Piece IOL

Tecnis Puresee[^TM] IOL Model DENooV

TECNIS PureseeTM IOL

Excellent distance, intermediate and functional near vision7,8

PureSee infographic

TECNIS PureSee IOL provides monofocal-like quality of vision9

3 month mesopic no glare

3-Month Mesopic No Glare

3-Month Mesopic With Glare

3-Month Mesopic With Glare

Ease of Use

TECNIS PureSee IOL

Provides high tolerance to refractive error and delivers good outcomes event under defocus2,14-15

Document TECNIS PureSee[^TM] IOL

Patients show high satisfaction and recommend the lens16

PureSee Graphic Landingpage

Preloaded in the TECNIS SIMPLICITY Delivery System

Designed for controlled and easy delivery17

Simplify lens delivery with

TECNIS Simplicity

TECNIS Simplicity™

Delivery System Preloaded with TECNIS PureSeeTM IOLs

Improve efficiency with a simple 3-step process17

  1. Hydrate
  2. Advance
  3. Deliver

Eliminate manual loading errors and IOL touches1

Minimise risk of infection associated with contamination1

TECNIS Toric II Platform

Toric platform graphic

Lock-in visual performance with TECNIS PureSee Toric II IOL

 

Frosted haptic design increases the amount of friction between the lens haptic surface and the capsular bag to lock in the IOL for rotational stability and visual performance.18,9

TECNIS PureSee IOL

Polished haptics

TECNISTM Toric II IOL key study results

Squared and frosted haptics

Exceptional mean rotational stability of 0.94º at 3 months after surgery19 100% ≤5º rotation at 3 months19

REFERENCES
1. TECNIS PureSee IOL with TECNIS SIMPLICITY delivery system, model DEN00V, DfU INT, Z311973, current revision.
2. DOF2023CT4011 – Simulations of visual symptoms under defocus for TECNIS PureSee IOLs. 29 March 2023.
3. UN – Department of Economic and Social Affairs. Leaving no one behind in an ageing world – World Social Report 2023. REF2023CT4338.
4. Szanton SL, et al. Older adults’ favorite activities are resoundingly active: findings from the NHATS study. Geriatr Nurs 2015;36(2):131-135. REF2021OTH4024
5. Grzybowski A, et al. Methods for evaluating quality of life and vision in patients undergoing lens refractive surgery. Graefes Arch Clin Exp Ophthalmol 2019;257:1091-1099. REF2021CT4246.
6. DOF2023CT4012 – Photic phenomena evaluation of the TECNIS PureSee IOL using natural images. 29 March 2023.
7. DOF2023CT4016 – Simulated VA of the TECNIS PureSee IOL compared to TECNIS Eyhance and TECNIS 1-Piece IOL. 29 March 2023.
8. DOF2023CT4027 – Simulated VA of the TECNIS PureSee IOL compared to TECNIS Symfony IOL. 15 March 2023.
9. DOF2023CT4036 – Clinical investigation of the TECNIS IOL, models C1V000 and C2V000. Contrast sensitivity outcomes. 17 July 2023.
10. DOF2023CT4017 – MTF of the Bausch & Lomb LuxSmart IOL. 28 March 2023.
11. DOF2023CT4018 – MTF of the SIFI MiniWell IOL. 28 March 2023.
12. DOF2023CT4028 – Simulated VA of the TECNIS PureSee IOL compared to Vivity. 24 April 2023.
13. DOF2023CT4025 – MTF of TECNIS PureSee IOL and other lens models in low-light conditions. 4 April 2023.
14. Black D, et al. Clinical evaluation of tolerance to residual refractive errors following implantation with a refractive extended-depth-of-focus (EDF) IOL. Abstract ESCRS 2023. REF2023CT4129
15. DOF2023CT4041 – Clinical investigation of the TECNIS IOL, models C1V000 and C2V000. Tolerance to refractive error. 17 July 2023.
16. DOF2023CT4043 – Clinical investigation of the TECNIS IOL, models C1V000 and C2V000. Patient satisfaction outcomes. 18 July 2023.
17. Delta IOL delivery system – Human factors validation report. Dec. 12, 2018. REF2019CT4449.
18. TECNIS PureSee toric IOL with TECNIS SIMPLICITY delivery system, model DET00, DfU INT (DET100-DET600), Z311783, current revision.
19. DOF2021CT4019 – Clinical investigation of rotational stability of the TECNIS toric II IOL – Steele study – NXGT-202-QROS. 20 Aug. 2021


For healthcare professionals only. Please reference the Instructions for Use for a complete list of Indications and Important Safety Information and contact our specialists in case of any question.

2024PP05464 v2.0